Paradyne COMSPHERE 3610 Replacement Manual

Data service units documentation replacement
Hide thumbs Also See for COMSPHERE 3610:

Advertisement

COMSPHERE
3600 SERIES
DATA SERVICE UNITS
MODELS 3610 AND 3611
DOCUMENTATION REPLACEMENT
Document No. 3610-A2-GB43-50
Feature No. 3600-G3-002
December 1996

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne COMSPHERE 3610

  • Page 1 COMSPHERE 3600 SERIES DATA SERVICE UNITS MODELS 3610 AND 3611 DOCUMENTATION REPLACEMENT Document No. 3610-A2-GB43-50 Feature No. 3600-G3-002 December 1996...
  • Page 2 COMSPHERE 3600 Series Data Service Units COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Documentation Replacement 3610-A2-GB43-50 Feature No. 3600-G3-002 6th Edition (December 1996) Changes and enhancements to the product and to the information herein will be documented and issued as a new release.
  • Page 3: Important Safety Instructions

    Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. – Do not use the telephone to report a gas leak in the vicinity of the leak. 3610-A2-GB43-50 December 1996 Safety Instructions...
  • Page 4 COMSPHERE 3600 Series Data Service Units Notices December 1996 3610-A2-GB43-50...
  • Page 5: Government Requirements

    RENs of all devices should not exceed 5. Call your local telephone company to ascertain the maximum REN for your calling area. If your Model 3610 or 3611 DSU with DBM causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance.
  • Page 6 The DDS Service Order Number is 6.0Y. The jack configurations required are RJ48S for the Model 3610 DSU and RJ48T for the Model 3611. With the Model 3611 RJ48T configuration, you must specify the number of data lines you require. Refer to Chapter 1, For DBM installations, the proper service and jack must be ordered from the telephone company.
  • Page 7: Equipment Warranty And Support

    — Within the U.S.A., call 1-800-870-2221 — International, call 727-530-2340 If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved. 3610-A2-GB43-50 section. CAUTION December 1996...
  • Page 8: Reference Documents

    Dial Backup Modules (DBMs), Time Division Multiplexer (TDM), Multichannel Multipoint (MCMP) and the digital bridge options. Chapter 2 describes electrical connection of the Model 3610 DSU, as well as Digital Data Service (DDS), Switched 56 kbps, dial, and ISDN networks. 3610-A2-GB43-50 Preface Reference Documents ANSI X3.64 –...
  • Page 9 Supplement to the User’s Guide. Ships with all standalone 3610 DSUs with TDM, MCMP, or Digital Bridge options or upgrades. Provides descriptions of TDM, MCMP, and Digital Bridge features, installation instructions, front panel operation, configuration options and worksheets, troubleshooting, messages, and specifications.
  • Page 10: Technical Specifications

    AC POWER FUSE Model 3610/3611 DSU 3000 Series Carrier AC POWER REQUIREMENTS 3610 DSU 3610 DSU with DBM 3611 DSU 3611 DSU with DBM DBM (V.32 or Switched 56) 3000 Series Carrier (16 DSUs with DBMs plus SDU and fan module) 3610-A2-GB43-20 V.34 DBM and DBM-F...
  • Page 11 3611 DSU, 3000 Series Carrier Safety 3610 DSU 3611 DSU, 3000 Series Carrier Emissions Bell Canada DTE INTERFACE 3610 and Non-modular 3611 DSUs 25-pin D-subminiature connector 34-pin connector Modular 3611 DSU 25-Pin V.35 Interface Uses a Rear Connector Plate with two 25-pin D-subminiature connectors...
  • Page 12 Depth (25-Pin V.35 Interface) 3000 Series Carrier Height Width Depth WEIGHT 3610 DSU 3610 DSU with DBM 3611 DSU (modular) 3611 DSU (modular) with DBM 3611 DSU (non-modular) 3611 DSU (non-modular) with DBM Rear Connector Plate (2-port) 25-Pin EIA-232/25-Pin V.35...
  • Page 13 Digital Services (DDS, ASDS) LADS Clear Channel When timing is external (provided by the DTE), the DTE’s clock must be within these ranges. DDS NETWORK INTERFACE 3610 DSU 3611 DSU DIAGNOSTIC INTERFACE 3610 DSU 3611 DSU NETWORK COMPATIBILITY ANSI T1.410 – 1992 and AT&T Technical Reference 62310 –...
  • Page 14 WEIGHT 3610-A2-GB43-20 Table 1-3 Criteria Diagnostic interfaces for the Model 3610 DSU Two 8-pin modular jacks (Note that the 3600 Hubbing Device has a 6-inch attached cable that terminates in a 4-pin modular plug.) 1.9 inches (4.8 cm) 0.9 inches (2.3 cm) 3.4 inches (8.6 cm)
  • Page 15 DBM COMPATIBILITY RECEIVE VF INTERFACE Dynamic Range V.32 2-wire PSTN Impedance SWITCHED NETWORK INTERFACE 3610 DSU 3611 DSU TRANSMIT VF INTERFACE Signal Level V.32 2-wire PSTN Impedance If a non-3600 Series DBM V.32 modem calls into the DBM with firmware version 2.8 or lower, a manual switch to the Dial command is required to complete the backup process.
  • Page 16 Transmitter Receiver COMMUNICATION LINE DATA RATES DBM COMPATIBILITY RECEIVE VF INTERFACE Dynamic Range V.34 2-wire PSTN Impedance SWITCHED NETWORK INTERFACE 3610 DSU 3611 DSU TRANSMIT VF INTERFACE Signal Level V.34 2-wire PSTN Impedance 3610-A2-GB43-20 Table 1-5 Criteria DBM option 0.2B...
  • Page 17 Load Number APPLICATION COMMUNICATION LINE DATA RATES DBM COMPATIBILITY SWITCHED 56 KBPS NETWORK INTERFACE 3610 DSU 3611 DSU NETWORK COMPATIBILITY Table 1-6 Criteria 230 5870 A Full- or half-duplex data transmission via 56 kbps switched services compatible with AT&T, US SPRINT , and MCI using DataPath...
  • Page 18 Specifications APPLICATION COMMUNICATION LINE DATA RATES DBM COMPATIBILITY SWITCHED 56 KBPS NETWORK INTERFACE 3610 DSU 3611 DSU NETWORK COMPATIBILITY 3610-A2-GB43-20 Table 1-7 Criteria Full- or half-duplex data transmission via 56 kbps switched services compatible with AT&T, MCI, and US SPRINT using 4-wire switched access...
  • Page 19 CHANNEL EQUALIZATION Receiver COMMUNICATION LINE DATA RATES DBM COMPATIBILITY RECEIVE INTERFACE Dynamic Range Impedance SWITCHED NETWORK INTERFACE 3610 DSU 3611 DSU TRANSMIT INTERFACE Signal Level Impedance 1-10 Table 1-8 Criteria 230 6943 A Full-duplex data transmission via ISDN BRI U-Interface for point-to-point or...
  • Page 20 Digital sharing FEP port sharing Digital bridge PORT SYNCHRONOUS RATES PORT ASYNCHRONOUS RATES PORT DTE INTERFACE 3610 DSU (2-port TDM/Flex) 3610 DSU (6-port TDM/Flex) 3611 DSU (modular) 3610 DSU (TDM/DSD) 3611 DSU (non-modular) NMS SUPPORT TDM and MCMP circuit cards can be configured to provide TDM capability.
  • Page 21 NUMBER OF TRIBUTARIES LINE SPEEDS CHANNEL SYNCHRONOUS RATES Primary (DSU) CHANNEL ASYNCHRONOUS RATES PORT DTE INTERFACE 3610 DSU (2-port MCMP/Flex) 3610 DSU (6-port MCMP/Flex) 3611 DSU (modular) 3610 DSU (MCMP/DSD) 3611 DSU (non-modular) NMS SUPPORT Only MCMP circuit cards can be configured to provide MCMP capability.
  • Page 22 Digital Bridge PORT SYNCHRONOUS RATES Primary (DSU) and Backup (DBM) DIAGNOSTIC SUPPORT PORT DTE INTERFACE 3610 DSU (2-port TDM/Flex or MCMP/Flex) 3610 DSU (6-port TDM/Flex or MCMP/Flex) 3611 DSU (modular) 3610 DSU (TDM/DSD or MCMP/DSD) 3611 DSU (non-modular) NMS SUPPORT TDM and MCMP circuit cards can be configured to provide digital bridge capability.
  • Page 23: Table Of Contents

    ............. Switched 56 kbps Network Connection ISDN DBM Network Connection Overview The Model 3610 DSU is delivered with default hardware strap settings and factory-installed software options. The DSU is ready to connect to the network. No on-site assembly is required.
  • Page 24: Installing The Dsu

    COMSPHERE 3600 Data Service Units Installing the DSU The Model 3610 DSU is designed for desktop operation. Place the DSU in the planned location. Allow 1 to 2 feet of clearance for cable connections, space for the ventilation slots on the sides, and clearance at the rear for the cable connections.
  • Page 25: Dds Network Connection

    RJ48S Wall Jack 495-14578-02 Refer to the Verifying the V.32 DBM Hardware Settings section in the DBM Supplement for hardware strap details. December 1996 Model 3610 Installation Dial Network Connection Backup V . 3 / D C L I N...
  • Page 26: Switched 56 Kbps Network Connection

    Refer to the Configuration Branch section in Chapter 3 and Appendix C, Ordering ISDN Service, in the DBM Options Supplement for details. 495-14860 December 1996 ISDN Backup V . 3 / D C L I N SJA11 U-Interface Connector 495-14580-01 3610-A2-GB43-50...

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series

Table of Contents