Dsu Configuration Options - Paradyne COMSPHERE 3610 Operator's Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

Rate(Kbps): 9.6
Next
64CC
64L
1
DSU Rate .
Data rate (in kbps) on the digital circuit. Must be set to match the speed of the DDS circuit.
64CC —
64 kbps Clear Channel (on a 72 kbps circuit) with 3600 Series DSUs at both ends of the circuit.
64L
64 kbps LADS operation.
NOTE: The control and tributary DSUs must be set to the same value.
PrtSp(Kbps): 9.6
Next
64
56
12.0
9.6
9.2
2
Port Speed .
Sets the speed of the DTE port interface. The port speed may be set to any value less than or
equal to the Rate(Kbps) configuration option value. If the value is set less than the DDS rate, the DSU
performs rate adaption.
64
Select the DTE's port speed. The following port speeds do not appear in MCMP mode: 64, 56,
to 1.2
32, 28.8,18.8, 18.0, 9.2, 8.4, 4.4, 4.0, and 2.0.
Disab —
Disable port speed.
TxClkSource: DDS
Next
Int
RXC
Transmit Clock Source .
Int
Internal clock source. Timing is taken from the DSU.
RXC
Receive clock source. The DSU generates its transmit timing from the receive data signal. This
choice is provided for LADS configurations. It differs from the DDS selection during tests.
Ext
External clock source. The DSU is timed by the external Transmit Timing lead on Port 1 only.
Ports 1 — 6. The DSU is timed by the external Transmit Timing lead on the specified to
Prt1 to —
Prt6
port.
DDS
DDS Network. This source is used when the DSU is connected to a DDS network and the
network provides the timing.
1
If operating in MCMP mode (MUX Funct is set to MCMP), the Rate(Kbps) default is 56.
2
Port speed does not appear if TDM or MCMP hardware is installed and MUX Funct is set to TDM, MCMP,
EBrdg, or CBrdg. Instead, this entry is made in the Port Speed (PrtSp) Configuration Options for DSU with
TDM
(Table
6-14) or the Port Speed (PrtSp) Configuration Options for DSU with MCMP
Configuration Options Tables
to the list in the
3
In TDM and MCMP mode, the Ext clock source is replaced with Prt1, Prt2, Prt3, Prt4, Prt5, Prt6. Selecting a
port setting means that the TDM will operate with timing provided by the DTE at the designated port
(EIA-232 Pin 24 or V.35 Pins U and W).
For CBrdg mode in full backup and EBrdg mode, timing is set using the Bridge Timing configuration option
in Table 6-11,
Digital Bridge Setup Configuration
3610-A2-GB91-90

DSU Configuration Options

56
38.4
19.2
48
38.4
32
8.4
7.2
4.8
Ext
Prt1
Prt2
3
Specifies the transmit timing source for the DSU.
section.)
Table 6-1
(1 of 3)
9.6
4.8
2.4
28.8
19.2
18.8
4.4
4.0
2.4
Prt3
Prt4
Prt5
Options.
July 1999
Configuration Options
Prev
18.0
16.8
14.4
2.0
1.2
Disab
Prt6
DDS
(Table
6-15). (Refer
Prev
Prev
6-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series