COMSPHERE 3600 Series Data Service Units
Tributary 3610 DSUs can be configured from an NMS
provided:
The Position configuration option is set to Trib
from the DCP
The DSU is connected to a control DSU that is
connected to the NMS
The COMSPHERE 6700 or 6800 Series NMS,
which uses the Advanced Diagnostic protocol (ADp),
fully supports configuration of the DSUs. When using
either the DATAPHONE II (DPII) or Diagnostic
MicroComputer (DMC) protocol, the following
limitations apply:
Only a subset of the configuration options or other
configuration parameters can be displayed from the
DATAPHONE II System Controller.
Only a subset of the configuration options or other
configuration parameters can be displayed from the
ANALYSIS 6510 NMS.
The DATAPHONE II System Controller console
displays 3600 Series DSU configuration options in a
matrix-coded format. The matrix consists of 11 rows,
labeled A through K, and eight columns, labeled 1
through 8. For example, position G6 represents the option
Link Configuration:
G6 ON = Pt-Pt
G6 Off = M-Pt
For more information on the matrix-coded format
and/or the NMS commands, refer to your NMS
documentation.
DDS (or LADS)
Network Connection
NOTE
Before connecting the DSU to the
DDS network, ensure that
approved primary protectors have
been installed on the circuit in
accordance with Article 800 of the
National Electric Code, NFPA 70,
in the United States and
Section 60 of the Canadian
Electric Code, Part 1, in Canada.
2-10
To connect the DSU to the DDS (or LADS) network:
"
Procedure
1. Plug the DDS network interface cable into the
DSU jack labeled LINE (refer to Figure 2-6).
U.S. – select either end of the cable
Canada – select the 8-pin end
2. Plug the other end of the cable into the modular
jack (USOC RJ48S) provided by the circuit
provider.
If the remote DSU is also connected to the network, the
DSU's green OK indicator lights and the Alrm indicator
goes off. The Health and Status screen no longer displays
a No Signal message.
If connecting the DSU to a LADS network, there are
distance limitations that govern the use of DSUs on the
network. For further information, refer to the
Operation
section of Chapter 1.
Figure 2-6. Model 3610 DSU DDS Network

LADS Connection

If connecting to a (LADS) network, refer to the
Operation
section of Chapter 1 for distance limitations
governing the use of 3600 Series DSUs for LADS
connections.