Dds Network Connection; Lads Connection - Paradyne COMSPHERE 3610 Operator's Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

COMSPHERE 3600 Series Data Service Units
When configuration options are changed through an
NMS routine, a Display command can be executed (i.e.,
dso) to verify that the Change command was successful.
The tributary 3611 DSUs can be configured from an
NMS provided the Position configuration option is set to
Trib from the DCP and the DSU is connected to a control
3611 DSU that is connected to the NMS.
The COMSPHERE 6700 or 6800 Series NMS, which
uses the Advanced Diagnostic protocol (ADp), fully
supports configuration of the DSUs.
For more information on the matrix-coded format
and/or the NMS commands, see the COMSPHERE
6800 Series Network Management System
Communications Products Support Command Reference
Manual or the COMSPHERE 6700 Series Network
Management System, User's Guide.
When using either the DATAPHONE II (DPII) or
Diagnostic MicroComputer (DMC) protocol, the
following limitations apply:
Only a subset of the configuration options or other
configuration parameters can be displayed from the
DATAPHONE II System Controller.
Only a subset of the configuration options or other
configuration parameters can be displayed from the
ANALYSIS 6510 NMS.
The DATAPHONE II System Controller console
displays 3600 Series DSU configuration options in a
matrix-coded format. The matrix consists of 11 rows,
labeled A through K, and eight columns, labeled
1 through 8. For example, position G6 represents the
option Link Configuration:
G6 ON = Pt-Pt
G6 Off = M-Pt
Refer to
Appendix I
for a complete description of the
DATAPHONE II option matrix and the option value
represented at each position.
options, while
Appendix K
3-10
Appendix J
lists the DMC
lists the DMC commands.

DDS Network Connection

Before connecting the DSU to the
DDS network, ensure that
approved primary protectors have
been installed on the circuit in
accordance with Article 800 of the
National Electric Code, NFPA 70,
in the United States and Section
60 of the Canadian Electric Code,
Part 1, in Canada.
The DDS network interface is provided by two RJ48T
50-pin connectors on the back of the carrier
DDS Interface). Each connector serves eight contiguous
slots in the carrier: one for Slots 1 through 8 and one for
Slots 9 through 16. The pin assignments are listed in
Appendix
F. Refer to the COMSPHERE 3000 Series
Carrier, Installation Manual for installation procedures.
Appendix E
provides connectivity diagrams should
you need further assistance in connecting the DSU to the
network.

LADS Connection

If connecting to a local area data set (LADS) network,
refer to the
LADS Operation
distance limitations governing use of the 3600 Series
DSUs for LADS connections.
July 1999
NOTE
(Figure
3-4,
section of Chapter 1 for
3610-A2-GB91-90

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series

Table of Contents