Procedure
1. Watch the LCD during the tests.
Power-Up Tests
Please Wait . . .
F1
The results of each test display briefly as Pass,
Fail, or Abrt. The tests take about 20 seconds to
complete. You are looking for successful test
results.
DSU MUX
Pass Pass
F1
2. Continue if you receive successful messages. If a
Fail message appears or an installed hardware
option does not appear, refer to Appendix E,
Troubleshooting and Front Panel Messages.
The DSU power-up routine can be:
Initiated using the Reset selection in the Control
branch.
Disabled with the PowerOnTst General
configuration option.
3610-A2-GB46-60
F2
F3
F2
F3
December 1996
Saving and Changing
Configuration Options
For Model 3610 and Model 3611 DSUs, change
configurations options from:
A front panel, or
A 6700 or 6800 Series NMS, or
An async terminal (Model 3610 standalone only)
Appendix B provides a Basic Configuration
Worksheet, which is a summary of Basic DSU mode
configuration option sets. Use the worksheet, the menu
tree in Appendix A, and Chapter 4, Configuration Option
Tables, for reference.
Configuration options supporting TDM, MCMP, and
digital bridging are in Document No. 3610-A2-GB48.
Configuration options supporting DBMs are in
Document No. 3610-A2-GB49.
The Model 3610 is preconfigured at the factory for
FacT with default settings for a tributary, point-to-point
circuit, and a data rate of Auto. Set the data rate to match
the service provider's rate.
If you have a point-to-point configuration:
Enable one unit as the control
Enable the other unit as the tributary
Set the link configuration option (Table 4-3)
Model 3610 Installation