Paradyne COMSPHERE 3610 Operator's Manual page 208

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

COMSPHERE 3600 Series Data Service Units
Message
OutofFrame Thresh
Port nn DTR Alarm
Prt nn Disable
Prt nn StreamTerm
P nn Tst: test, init
Redun Fan Alarm
Redun Pwr Alarm
Subnetwrk Alarm
Sub-normal Speed
Subtree Truncat
C-6
Table C-4
(4 of 5)
Device Health and Status Messages
For DSUs operating on a single port (rate adaption or nondisruptive), TDM, or
MCMP, the local DSU has detected a continuous MUX Out-of-Frame condition.
The alarm clears when a local DSU synchronizes with a remote DSU.
On a point-to-point circuit, if the alarm continues and the local DSU is
configured for automatic backup, the local DSU disruptively tests the DDS
circuit. If the test fails, the local DSU initiates a DDS Facility Alarm and initiates
dial backup.
The DTR lead at port nn (01—06, All) has been Off for more than 30 seconds.
Transmitter at port nn (01—06, All) is disabled. Go to the Control Branch to
enable the port.
Streaming terminal. DTE at port nn (01—06, All) has its RTS lead turned ON
longer than the predefined time.
The DSU is running a test on port nn (01—06), initiated from init .
test is one of the following tests:
BERT — Bit Error Rate Test
DL
— Digital Loopback
DT
— Digital Test
DTE
— DTE Loopback
RL
— Remote Digital Loopback
init is one of the following initiators:
DTE
— Data Terminal Equipment
FP
— Front Panel (the DCP)
LPDA — NetView-initiated test
NMS
— Network Management System
Remt
— Remote DSU
TM
— Test Mode
Indicates a problem with the fan on the – 48 Vdc Central Office Power Unit.
Indicates a problem with the power on the – 48 Vdc Central Office Power Unit.
A major alarm was set Off by one of the devices in your subnetwork. Check the
Subnetwork Health and Status report.
The DSU is operating at a dial backup speed that is less than the DDS network
speed.
Downstream health and status information has been truncated because it
overflowed system limits.
July 1999
Condition
3610-A2-GB91-90

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series

Table of Contents