COMSPHERE 3600 Series Data Service Units
Message
DBMTst: test , init
DDS F: alarm
Dial Tone:Fail
DSU:Device Fail
DSU:Disable
C-4
Table C-4
(2 of 5)
Device Health and Status Messages
The DBM is running a test, initiated from init .
test is one of the following tests:
BERT — Bit Error Rate Test
BiL
— Bilateral Loopback
Dev
— Device Test
DL
— Digital Loopback
DT
— Digital Test
DTE
— DTE Loopback
E-E
— End-to-End Test
Lamp
— Lamp Test
LL
— Local Loopback
NetL
— Network Loopback (Switched 56 DBM only)
RL
— Remote Digital Loopback
TM
— Test Mode
init is one of the following initiators:
DTE
— Data Terminal Equipment
FP
— Front Panel (the DCP)
LPDA — NetView-initiated test
NMS
— Network Management System
Ntwk
— Network (Switched 56 DBM only)
Remt
— Remote DSU
Digital facility alarm; alarm is one of the following network alarms:
AbnStatCod — Abnormal Station Code.
BiplrViol
— Excessive Bipolar Violations.
Fac Alarm
— Facility Alarm.
OutofServc — Out-of-Service condition.
No Signal
— No signal has been received.
Dial tone test was enabled and test failed.
Internal failure in the DSU is detected. Go to the Test Branch for Device Test.
DSU transmitter is disabled. Go to the Control Branch to enable the DSU.
July 1999
Condition
3610-A2-GB91-90