Ferrite Choke
Installation Instructions
Document Number 3610-A2-GZ41-70
April 1999
Overview
This document describes the procedure for installing a
ferrite choke onto a cable, and accompanies at least one
ferrite choke.
One ferrite choke is provided with every:
Model 3511, 3611, and 3616 DSU with a Dial
Backup Module (DBM). Attach the ferrite choke to
the DTE cable.
DBM shipped as a separate feature. Attach the
ferrite choke to the DTE cable for a carrier
installation, and discard it for a standalone unit.
Two or more ferrite chokes are provided with every:
Model 3000 Carrier assembly with an ac power
transformer unit. Attach one ferrite choke to the ac
power cord and one to each network cable.
Model 3611 MUX circuit card. Attach one ferrite
choke to each DTE cable.
Six-Port MUX Adapter module. Attach one ferrite
choke to each DTE cable.
CAUTION
All ferrite chokes that are
supplied must be installed
following these instructions
to ensure compliance with
FCC Part 15 Rules.
3610-A2-GZ41-70
TM
April 1999
Installation
To install the ferrite choke on the DTE interface,
network, or power cable:
"
Procedure
1. Pull up on the latch to open the ferrite choke.
2. Place the ferrite choke around the cable as close to
the cable connector as possible.
3. Close the two halves around the cable and snap
the ferrite choke shut.
Ferrite Choke
Tie
Wrap
4. Press down on the plastic latch to secure the ferrite
choke in place around the cable.
5. For the ac power cable or other thin cable, secure
the ferrite choke in place with a cable tie wrap.
Refer to Figure 1 on the next page for examples of
installed ferrite chokes.
Plastic
Latch
496-14820-01
1

Advertisement

loading

Summary of Contents for Paradyne 3610

  • Page 1 Ferrite Choke Installation Instructions Document Number 3610-A2-GZ41-70 April 1999 Overview This document describes the procedure for installing a ferrite choke onto a cable, and accompanies at least one ferrite choke. One ferrite choke is provided with every: Model 3511, 3611, and 3616 DSU with a Dial Backup Module (DBM).
  • Page 2 EIA-232 Interface 3600 V.35 Interface V.35 Cable Figure 1. Examples of Installed Ferrite Chokes, Carrier Rear View *3610-A2-GZ41-70* Copyright E 1999 Paradyne Corporation Ferrite Choke for V.32 DBM or DBM-V Cable Tie Wrap for AC Power Cable Network Cable *3610–A2–GZ41–70*...

This manual is also suitable for:

3511361136163000