Terminal Power

The Terminal Power (TPwr) report is a display
showing the status of the connected DTE's EIA-232 and
V.35 interface. The DSU checks the state of the
request-to-send (RTS) lead and reports the DTE powered
ON if the voltage is approximately less than –2V or
greater than +2V for both the EIA-232 or V.35 interfaces.
To access the Terminal Power report from the top-level
menu, make the following selections:
Local (F1), or Remot (F2) and Address
Stat
TPwr
Results
The following report displays for the local or remote
device selected:
Prt1 Term Power:
On
F1
F2
If power is detected on the RTS lead, the second line
displays On. If no power is detected on the RTS lead, the
second line displays Off.

Backup Branch

The Backup (Bckup) branch controls operation of the
point-to-point dial backup feature. The Bckup selection
only appears when a DBM is installed, Central-Site
Bridge (CBrdg) is enabled, or Aggregate Switch
(AggrSwitch) is enabled.
Refer to COMSPHERE 3600 Series Data Service
Units, Models 3610 and 3611, Dial Backup Module and
SNA Diagnostic Interface Options, Applications Guide for
dial backup information.
For Central-Site Bridge and DBM-V, DBM-S, and
DBM-D information, see the COMSPHERE 3600 Series
Data Service Units, Models 3610 and 3611, Time Division
Multiplexer, Multichannel Multipoint, and Digital Bridge
Options, Applications Guide.