Paradyne COMSPHERE 3610 Operator's Manual page 282

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

COMSPHERE 3600 Series Data Service Units
NMS Command
Long Status
Loopback Test
Reset DMC
1
Strap Device
Transmission Test
1
These selections are described in more detail in
2
A DBM speed of 12 kbps is reported as 64 kbps.
K-2
Table K-1
(2 of 2)
ANALYSIS 6510 NMS DMC Commands
When addressed to a DSU or DBM, returns identity information, including
device type (reported as a 2696 for a 3611 and 2656 SC for a DBM).
The MSDU firmware level is used to report the actual model number of the
DSU in the form 36.11.00. The DSU firmware level shows the DSU's firmware
version.
Causes the DSU or DBM to perform the specified loopback test. Possible
loopback tests are: DTE Loopback (Local Loopback), Local Digital Loopback,
and Remote Digital Loopback.
Returns either an A (ACK) or N (NACK).
Causes the DSU to abort all test conditions and return to normal operations.
It does not enable/disable a DSU or DBM that was disabled by the DSU
Disable command.
If the addressed DSU is not in a test mode, no action is taken. Returns an
A (ACK) or N (NACK).
Reads option settings from the control DSU or DBM and returns the following
information about the DSU or DBM:
Timing
Tributary Type
Respond to RDL
RTS Control
DSR On in Local Loop
Streaming Terminal
Circuit Assurance
System Status
Elastic Store
2
DSU Speed
RS Call Control (DBM only)
DTR Call Control (DBM only)
CRQ Disconnect Control (DBM only)
Causes the DSU to put the addressed tributary DSU in remote digital
loopback and transmit a test pattern. The returned data is checked for errors.
Returns Pass, Fail, or Test in Progress.