COMSPHERE 3600 Series Data Service Units
AntiStream:Disab
Next
Chang
Prev
Antistreaming . Antistreaming provides circuit protection against a streaming DTE (a defective DTE that has
its RTS lead constantly turned ON) by clamping the RTS lead of the tributary DSU.
In TDM or MCMP mode, the DSR FrcOn and DSR on Tst configuration options are not displayed; rather, you
select these configuration options on a per-port basis in the MUX submenu.
If the tributary DTE turns ON RTS longer than the time specified for the AntiStream configuration option, the
tributary DSU turns on its alarm indicator and clamps RTS to Off. Although the tributary DTE is not allowed
to send, the DSU can still respond to commands and is capable of being tested or disabled.
Upon detecting that RTS is no longer turned ON, the DSU turns Off its alarm and resets the streaming timer,
and allows the DTE to send data once again.
This configuration option only has an effect at a DSU configured with RTS Control set to DTE. It is disabled
when RTS Control is set to FrcOn.
Chang —
Set timer to Disab or any value from 1 to 100 second(s) in increments of 1. When Disab is
selected, streaming terminal detection is not provided. When using async terminal, enter
0 (zero) to disable.
LSD Lead: Std
Next
Std
Delay
Line Signal Detect Lead . Controls behavior of the Line Signal Detect lead.
Std
LSD lead goes Off in response to a control mode idle (CMI) signal from the DDS network or
DDS failure.
1
Delay
LSD does not go Off in response to a network alarm condition or CMI. LSD goes Off only after
repeated call attempts fail and the Tries Time-out configuration option expires. Only use this
selection if Auto Bckup is enabled.
FrcOn —
Keeps LSD on as long as the DSU has power.
CTS Lead: Std
Next
Std
Delay
Clear-to-Send Lead . Controls the behavior of the Clear-to-Send lead.
The Std and Delay selections are ignored if RTS Control is set to DTE or if Circuit Assurance is enabled.
Std
CTS behavior is determined by the combination of the RTS Control and CTS Control
configuration options.
1
Delay
CTS does not go Off in response to a network alarm condition or CMI. CTS goes Off only after
repeated call attempts fail and the Tries Time-out configuration option expires. Only use this
selection if Auto Bckup is enabled.
FrcOn —
Keeps CTS on as long as the DSU has power.
1
Do not select Delay unless Auto Bckup = Enab in the Backup configuration option set.