To enable Term, a valid password must be entered from
the DCP. Enabling Term establishes async terminal
access.
Disab is the factory-loaded setting; the Term feature is
available, but disabled. To establish async terminal access,
you must enable the Term feature. Once async terminal
control is established, select Disab to return control of the
DSU to the DCP.
Password security protects access to the DSU. A valid
password can have up to 8 characters. Valid password
characters include letters a through z (both upper- and
lowercase), numbers 0 through 9, and the characters #,
dash ( – ), period (. ), or a slash ( / ). Contact your System
Administrator for access assistance.
Once async terminal access is established, the
Password Access Menu appears on the async terminal and
the password must be re-entered. (The DSU's DCP is
disabled and displays User I/F – Idle.)
If valid, the DSU's top-level menu is displayed on
the async terminal.
If invalid, the Password Access Menu reappears.
To change an existing password during an async
terminal session, select Pswrd and Chang from the Term
submenu. Enter the new password, press < CR>, and then
select 2 - Save.
To enter or change the customer identification that
appears at the top of each async terminal screen (e.g., to
change from a unit identifier to a site identifier), select
CID. Valid ID characters include letters A through Z,
numbers 0 through 9, and the characters #, dash ( – ),
period (. ), slash ( / ), or a space ( ).
Refer to
Async Terminal
additional information on managing the DSU using this
feature.

Control Branch

The Control (Ctrl) branch allows you to enable or
disable the DSU's transmitter, as well as the DBM's, and
to display or change the status of the general-purpose
external DTE leads.
3610-A2-GB91-90
Operation, Appendix D, for
To access the Control branch from the top-level menu
for Remote mode selections, enter the tributary address as
previously described in the
The Control branch menu has three selections.
Table 4-12 lists the selections on the Control branch
menu.

Control Branch Menu Options

Menu
Selection
TxCtl
LEDs
ExtL
1
Only applies to TDM or MCMP applications in
Local mode.
July 1999
DSU Operations
Remote Branch Menu
Table 4-12
Purpose
Enable or disable the DSU's
transmitter, or the DBM's call
setup or answer capability.
Selects whether the port or
aggregate data stream is
monitored on the faceplate
1
LEDs.
Status and control of two
external input leads and two
output leads available for
optional customer assignment.
section.
4-35