NOTE
The Digital Test command is not
available when the LPDA-2
configuration option is enabled.
The following selections are displayed:
DSU Digital Tst:
Start
Displ
F1
F2
If the Digital Test is already in progress, Start will not
be displayed.
For a DSU operating in single-port mode and having
either nondisruptive diagnostics or rate adaption in effect,
an additional selection for Aggr (Aggregate) or Prt1
(Port 1) appears:
Port Number:
Prt1
Aggr
F1
F2
Selecting Aggr (Aggregate) allows only the test pattern
data to propagate the looped data path; in-band secondary
channel transport data is not allowed, thereby disrupting
in-band secondary channel transport communications.
Selecting Prt1 (Port 1) allows both the test pattern and
in-band secondary channel transport data to propagate the
data path; in-band secondary channel transport
communications are preserved.
DSU Address: 1 2 3
F1
F2
The address of the tributary DSU being tested is
entered if the initiating DSU is a control. (This screen is
not displayed if the DSU is a tributary.)
3610-A2-GB91-90
Clr
F3
F3
Enter
F3
July 1999
RunTim:
F1
F2
In this example, the Digital Test has been set to run for
0 hours, 1 minute, and 9 seconds (format is hhh:mm:ss).
The
and
keys move the cursor to the right or left,
the F1 ( ) and F2 ( ) keys increment or decrement the
digits where the cursor is positioned. Selecting Enter
issues the DT command and returns you to the DSU
Digital Test screen.
DSU Digital Tst:
Command Complete
F1
F2
The test result is a message indicating whether or not
the loopback executed successfully.
Results
When the message Command Complete is displayed,
any key except the
key returns you to the Digital Test
submenu, where the Dsply and Clr selections display. In
the following example, DT ran for 1 minute and 9 seconds
with no errors and no error seconds.
DSU Digital Tst:
Displ
Clr
F1
F2
To review the results of the test, select Display (Displ)
and press the
key to scroll through the results shown
in
Table
4-6.
DSU DT: Final
Time:
F1
F2
DSU Operations
0:01:09
Enter
F3
F3
F3
0:01:09
F3