Paradyne COMSPHERE 3610 Operator's Manual page 194

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

Prt6 Options
Async Sync
Enab, Disab
Async Rate
=Sync, 1800, 1200, 600, 300, 150
AsyncBit/Char
6, 7, 8, 9, 10
Stop Bits
1, 2
Overspeed
1.25, 2.5
RTS Cntrl
FrcOn, DTE
TxCarrSel
Const, Cntrl
RxCarrSel
Const, Cntrl, Mark
PCC Buffer
Enab, Disab
Elast Stor
Enab, Disab
RTS/CTS Del
(Chang)
0–1040 ms
DTR Alarm
Enab, Disab
AntiStream
(Chang)
Disab, 1–100 sec
DSR FrcOn
Enab, Disab
DSR on Tst
Enab, Disab
Extend Chan
Yes, No
Upstrm Port
Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
DTE Port**
EIA232, V.35
DSU Options
Rate (Kpbs)
64CC, 64L, 56, 38.4, 19.2 9.6, 4.8, 2.4
TxClkSource
Int, RXC, DDS, Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
Msg Clamp
Enab, Disab
TxElasStor
Enab, Disab
RxElastStor
Enab, Disab
19.2 PowrLvl
+6, 0, –10
64KScrambling
On, Off
64KLatchLpbk
On, Off
AggrSwitch
Enab, Disab
AgSw Timing
Int, Aggr, Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
V.54 Lpbk
Enab, Disab
Configuration Worksheet for TDM Mode (2 of 3)
Value
PrtSp Options (DBM)
Prt1
Prt2
Prt3
Prt4
(8 ms increments)
Prt5
(async terminal = 0–100)
Prt6
Underspeed:
Diagnostic DBM
Options
Value
Diag Type
2nd Ch(bps)
RemoteDiag
Diagnostic DSU
Options
Diag Type
2nd Ch(bps)
Disr Type
**Available for TDM/Flex with DSU firmware version 6.3 x or greater
Value
(
)
56, 48, 38.4, 32, 28.8, 19.2, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
(
)
56, 48, 38.4, 32, 28.8, 19.2, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
(
)
56, 48, 38.4, 32, 28.8, 19.2, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
(
)
56, 48, 38.4, 32, 28.8, 19.2, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
(
)
56, 48, 38.4, 32, 28.8, 19.2, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
(
)
56, 48, 38.4, 32, 28.8, 19.2, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
Disab, Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
Value
NonD, Disr, Mixed, None
100, 400, 800, 1200, 1600
V.54, Enhan, 2500
Value
NonD, Disr, Mixed, None
100, 400, 800, 1200, 1600
2500, 2500, 3600s, 3600e, Br56
PrtSp Options (DSU)
Prt1
(
)
64, 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8,
14.4, 12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4,
2.0, 1.2, Disab
Prt2
(
)
64, 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8,
14.4, 12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4,
2.0, 1.2, Disab
Prt3
(
)
64, 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8,
14.4, 12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4,
2.0, 1.2, Disab
Prt4
(
)
64, 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8,
14.4, 12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4,
2.0, 1.2, Disab
Prt5
(
)
64, 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8,
14.4, 12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4,
2.0, 1.2, Disab
Prt6
(
)
64, 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8,
14.4, 12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4,
2.0, 1.2, Disab
Underspeed:
Disab, Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
Diagnostic General
Options
Position
Cntrl, Trib, G2Trb
LinkConfig
Pt-Pt, M-Pt
Resp Period
1, 2, 10
Trib TimOut
(Chang)
min and
sec
Diag Conn
CC, DC
Link Delay
0s, 1s, 2s, 5s, 10s, 20s, 50s
Network Delay
0s, 1s, 2s, 5s, 10s, 20s, 50s
Packet Delay
0s, 1s
2s, 5s
,
M-Pt SymPrt
Enab, Disab
Fast Sel
Enab, Disab
Value
Value

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series

Table of Contents