Digital Test - Paradyne COMSPHERE 3610 Operator's Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

COMSPHERE 3600 Series Data Service Units

Digital Test

Digital Test is accessed from the Test branch of the
second-level menu. Diagnostics (Diag) must be set to
active from the Confg branch first. To set the amount of
time for the Digital Test (DT):
"
Procedure
1. Select DSU from the DSU or DBM selection
screen; the DSU Tests selection screen appears
(Figure D-16).
PRESS: 4 – DT
2. The DSU Digital Test selection screen appears
(Figure
D-17).
PRESS: 1 – Start
3. The Port Number selection screen appears
(Figure
D-18).
PRESS: 2 – Prt1
1 – Abort
2 – Devic
3 – Lpbk
4 – DT
5 – EE
6 – BERT
7 – Lamp
PRESS Desired Selection Key
D-14
Customer ID: SITER170
Model: COMSPHERE 3610
DSU Tests:
Figure D-16. DSU Tests Selection Screen
July 1999
4. The DSU Digital Test Run Time input screen
appears
(Figure
D-19).
5. Enter the run time for the Digital Test and press
the carriage return < CR>. The following
message appears on the screen: Please wait.
NOTE
The run time input format is:
hhh:mm:ss where h=hours,
m=minutes, and s=seconds. All
fields must be fully populated;
i.e., 000:04:00.
6. The Digital Test completion screen appears
(Figure
D-20).
For further information on Digital Test, refer to
Table 4-5,
Test Branch Menu Selections for the
and the
Digital Test
section of Chapter 4.
T/ C t r l – T = Top Menu
U/ C t r l – U = Up Menu
C t r l – x = Disconnect
DSU,
3610-A2-GB91-90

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series

Table of Contents