Programming
19.4.27 Setting the Function modules parameter
This parameter provides virtual switches that can be assigned customer-
specific functions. They can be used when customer-specific applications
require a signal from the control of the machine.
This parameter cannot be used unless the function modules have been
assigned to a physical output at the Technician level. This requires that the
parameter Module management be configured at the technician level
( p. 157).
It is possible for each function module to place one function tile (stored) on
the main screen.
After the machine was switched on, the stepper motors need to perform a
reference run. Depending on the setting, referencing can be performed
automatically or by pressing the pedal back all the way.
Icon
19.4.28 Setting the Scanner parameters
The scanner can be activated or deactivated. A barcode scanner offers a
way to directly select a seam program.
Icon
The following types of barcodes can be read using the scanner:
The barcode types can be created with freeware software.
Service Instructions D867 e-con - 00.0 - 08/2023
Menu items
Only one active function mod-
ule is permitted
Function modules 1 - 8
Menu items
Scanner
P
Scan Program Barcode Strings
Barcode identification active
• Code 128
• UCC EAN 128
• Code 39
Value range
• Value range
On/Off
Inverted
• Value range
On/Off
Value range
• Value range
On/Off
• Value range
On/Off
• Value range
On/Off
155