Setting The Thread Trimmer Parameters - Dürkopp Adler D867 e-con Service Instructions Manual

Table of Contents

Advertisement

Programming
Icon

19.4.1 Setting the Thread trimmer parameters

Various settings can be made for the thread trimmer. The possibilities are
explained in more detail in the table.
Icon
Service Instructions D867 e-con - 00.0 - 08/2023
Menu items
RFID scanner
RFID
Desk height adjustment
Interface
Module management
Authentication methods
Energy Saving
Menu items
Thread trimmer
If deactivated here, the thread trimmer can no
longer be selected in the Manual or Automatic
Mode
Sewing speed
Speed of the machine during thread cutting
Start thread trim
Position when the magnet of the thread
trimmer is activated.
Stop thread trim
Position when the magnet of the thread
trimmer is deactivated.
Lower needle position
Needle position when sewing stops during
the seam, specified in degrees
Needle position after thread
trimming
Needle position after thread cutting before
reversal.
Explanations
 p. 156
 p. 156
 p. 156
 p. 157
 p. 161
 p. 161
Value range
• Value range
On/Off
• Value range
050 - 500 [rpm]
• Value range
000 - 359 [°]
• Value range
000 - 359 [°]
• Value range
000 - 359 [°]
• Value range
000 - 359 [°]