Dürkopp Adler D867 e-con Service Instructions Manual page 185

Table of Contents

Advertisement

Programming
Stitch length
6. Perform sewing test again and check the stitch length.
7. If the test run is the correct length, confirm with the Close button.
After calibrating the stitch length, it is advisable to perform another test in
standard sewing mode. Select a program that has an ornamental-stitch
bartack. Perform the test on paper again. The stitches should run neatly
into each other; if this is not the case, calibrate again.
Calibration of the Material thickness detection
Only one value needs to be checked when calibrating the material
thickness detection.
To calibrate the material thickness detection:
1. Call up the Service > Calibration > Material thickness
2. Follow the instructions on the display.
Calibration of the edge guide
To calibrate the lateral distance of the edge guide:
1. Flip up the edge guide.
2. Call up the Service > Calibration > Edge Guide menu item.
3. Confirm the selection with OK.
 The edge guide moves to the reference position.
4. Fold the edge guide down.
5. Measure the distance between the needle and the edge guide.
6. Enter the value with the -/+ buttons.
7. Confirm the entry with Next.
 The calibration is complete.
Service Instructions D867 e-con - 00.0 - 08/2023
-6
0
6
detection menu item.
Synchronization of the stitch length (ticks)
Reduce ticks – stitch length becomes smaller
Increase ticks – stitch length becomes larger
Reduce ticks – stitch length becomes larger
Increase ticks – stitch length becomes smaller
Reduce ticks – stitch length becomes larger
Increase ticks – stitch length becomes smaller
183