Service Instructions D867 e-con - 00.0 - 08/2023
Code
Type
Meaning
Information
Internal EEprom defective
Information
Internal EEprom defective and
external data not valid (emergency
operating features only)
Information
Internal EEprom defective and
external data not valid (emergency
operating features only)
Information
External CAN
Information
DACFlex not connected
Error
Stepper Puller Top reference drive
timeout
Error
Stepper Puller Top stepper motor
blockage
Error
Stepper Puller Top encoder plug not
connected
Error
Stepper Puller Top flywheel position
not found
Error
Stepper Puller Top not responding
Error
Stepper Puller Top initialization failure • Perform software update
Error
Stepper Puller Top overcurrent
Error
Stepper Puller Top revolution speed
Error
Stepper Puller Top watchdog
Error
Stepper Puller Top motor overload/
overvoltage/overcurrent
Error
Stepper Puller Top sewing motor
encoder not connected
Error
Stepper Puller Top sewing motor
encoder not initialized
Error
Stepper Puller Top init position not
found
Error
Stepper Puller Top not enabled
Error
Stepper Puller Top overload
Error
Stepper Puller Top encoder failure
Error
Stepper Puller Top Current sensor
failure
Corrective
• Replace the control
• Replace the control
• Replace the control
• Check connection cables
• Perform software update
• Replace CAN slaves
• Check DACFlex connection
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the
control
• Use correct connection
• Check stepper motor 1 for stiff
movement
• Perform software update
• Replace the control
• Check selection of class
• Check for stiff movement
• Speed of the Stepper Puller Top
• Perform software update
• Check selection of class
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor
• Connect encoder cable to the
control
• Use correct connection
• Replace the control