19.4.15 Setting the Needle Cooling parameters

Various settings can be made for the needle cooling. The possibilities are explained in more
detail in the table.
Icon
146
Menu items
Mode
t Delay
Lag time, after which the needle cooling is
deactivated.
Cool Speed
Speed at which the needle cooling is acti-
vated.
Service Instructions D867 e-con - 00.0 - 08/2023
Programming
Value range
• Value range
Off/
On/
Related to sewing
speed,
Edge trimmer
Only visible for Mode
On, Related to
sewing speed or Edge
trimmer
• Value range
00.0 - 10.0 [s]
Only visible for Mode
Related to sewing
speed
• Value range
0000 - 6000 [rpm]