Setting The Needle Thread Monitor Parameters - Dürkopp Adler D867 e-con Service Instructions Manual

Table of Contents

Advertisement

Icon

19.4.10 Setting the Needle thread monitor parameters

Icon
142
Menu items
Sewing foot lower position
Repeat message after trim
If an error is reported by the Loop Control,
Bobbin Rotation Monitor or remaining
thread monitor, the machine will indicate
an error message during the seam, which
must be confirmed. The error disappears.
If the parameter is active, the error will be
displayed again after the seam has been
completed.
Confirmation after sewing stop
necessary
If an error is reported by the Loop Control,
Bobbin Rotation Monitor or remaining
thread monitor, the machine will indicate
the error message and stop. You must
confirm this error before you can resume
sewing.
Loop Control
Bobbin Rotation Monitor
Menu items
Right side
Service Instructions D867 e-con - 00.0 - 08/2023
Programming
Value range
• Value range
On/Off
• Value range
On/Off
• Value range
On/Off
• Value range
On/Off
• Value range
On/Off
Length
Seam length before the
bobbin rotation monitor
starts.
• Value range
000 – 255 [mm]
Value range
On/Off
Speed
• Value range
0050 - 1000 [rpm]
Stitch delay
• Value range
000 - 255 [stitches]
Debouncing
• Value range
0000 – 5000 [ms]

Advertisement

Table of Contents
loading

Table of Contents