Fig. 58: Adjusting the needle thread regulator
(1) - Screw
(2) - Screw
To adjust the needle thread regulator:
1. Open the throat plate slide ( p. 28).
2. Turn the jog dial and observe the cycle of the needle thread around
3. Loosen screws (1) and (2).
4. Move the needle thread regulator (3)
5. Tighten screws (1) and (2).
72
the hook.
• Reduce the needle thread tension: Slide the needle thread
regulator (3) to the left
• Increase the needle thread tension: Slide the needle thread
regulator (3) to the right
Adjusting the needle thread tension
(3) - Needle thread regulator