132
Menu items
PWM Configuration thread
clamp
Power supply to the magnet for the
thread clamp
Neat seam beginning
Additional setting options are not visible
unless Neat Seam Beginning has
been activated.
Service Instructions D867 e-con - 00.0 - 08/2023
Programming
Value range
Activation time t1
[ms]
Activation duration of thread
clamp in time period t1.
• Value range
000 – 1000 [ms]
Duty cycle t1 [%]
Duty cycle in time period t1.
• Value range
000 - 1000 [%]
Time t2
Activation duration of thread
clamp in time period t2.
• Value range
000 - 1000 [s]
Duty cycle t2
Duty cycle in time period t2.
• Value range
000 - 1000 [%]
Boost
• Value range
On/Off
• Value range
On/Off
Time delay
• Value range
0000 – 1000 [ms]
Knife Off
• Value range
000 - 359 [°]
Clamp For Knife Off
• Value range
000 - 359 [°]
Exhaust On
• Value range
000 - 359 [°]
Exhaust Off
• Value range
00000 – 99999 [ms]