Programming
Operating Instructions 512/532 - 04.0 - 08/2016

5.24.2 Loading seam appearances

1.
Switch on the controller.
 The current software version is briefly shown in the display.
2.
Plug in the USB stick.
3.
Press the USB button and wait approx. 3 seconds.
4.
Press the Memory button.
5.
Press the P5 button.
 The download into the controller starts. Duration is approx.
4 min.
6.
Press the Reset button.
7.
Pull out the USB stick.
 The software transfer is complete.

5.24.3 Setting parameter U085 (Class 532)

With the button sewing machine, the parameter U085 must be set
after loading new software.
Prerequisite:
• Machine is in programming mode, Ready button LED is off.
1.
Press and hold the Memory button for 6 s.
 The button LED illuminates.
2.
Use the +/– Program buttons to set parameter number U085.
3.
Press the Ready button.
4.
Use the +/– Function buttons to enter a function value of 1.
5.
Press the Select button.