Configuration of the outputs
Configure and allocate the outputs here. The table shows the outputs and
their allocation. The pins on the PCB are labeled and must be allocated
according to the table, depending on what was connected to the pin.
One LED is lit at the LED modes. The output is set for as long as the
function is active.
Each output can be assigned one of the following modes.
Mode
Sewing foot lift
Needle thread tension
Bottom needle thread tension
Thread trimmer
Needle cooling
NSB knife
NSB block
Pos. 1
Pos. 2
Clean remaining thread monitor
Suppression bartack LED
2
2
2
Center guide LED
Raise/lower center guide
Motor running
2
NSB exhaust
Puller LED
Bartacking in process
In seam
Segment Output 01 - 16
Manual bartack
Stitch done
Motor blockage (operation lock)
Short stitch
Edge guide
160
nd
stitch length LED
nd
needle thread tension LED
nd
sewing foot stroke LED
nd
edge guide position LED
Explanation/reference
Operating Instructions/ p. 135
Operating Instructions/ p. 135
Operating Instructions/ p. 127
Operating Instructions/ p. 146
p. 131
p. 131
Bottom position of the sewing motor
Top position of the sewing motor
Output active during cleaning
Operating Instructions
Operating Instructions
Output active while motor is running
p. 131
Output active while bartacking is active
Output active while the machine is in the seam
Push button signal
p. 153
p. 162
Operating Instructions/ p. 150
Service Instructions D867 e-con - 00.0 - 08/2023
Programming