Troubleshooting
8175
8176
8177
8178
8179
8180
8181
8182
8183
8185
8186
8201
8208
8209
8232
8251
8258
8259
Service Instructions D867 e-con - 00.0 - 08/2023
Code
Type
Meaning
Error
Stepper Puller Bottom not enabled
Error
Stepper Puller Bottom overload
Error
Stepper Puller Bottom encoder failure • Connect encoder cable to the
Error
Stepper Puller Bottom Current sensor
failure
Error
Stepper Puller Bottom Incorrect
stepping motor direction of rotation
Error
Stepper Puller Bottom reference drive
failure
Error
Stepper Puller Bottom overcurrent
Error
Stepper Puller Bottom parameter
initialization
Error
Stepper Puller Bottom insulation error • Check motor phase and PE for
Error
Stepper Puller Bottom transport
interval failure
Error
Stepper Puller Bottom reference drive
failure
Error
Stepper card reference drive timeout
(Edge guide)
Error
Stepper card not responding
(Edge guide)
Error
Stepper card initialization failure
(Edge guide)
Error
Stepper card parameter initialization
(Edge guide)
Error
Stepper card reference drive timeout
(Edge guide)
Error
Stepper card not responding
(Edge guide)
Error
Stepper card initialization failure
(Edge guide)
Corrective
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor
control: Use correct connection
• Replace the control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine
distributor and change it if
necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Perform software update
• Check selection of class
low-impedance connection
• Replace encoder
• Replace motor
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
External Edge guide X Axis
• Check reference sensor
External Edge guide X Axis
• Perform software update
• Replace the control
External Edge guide X Axis
• Perform software update
• Check selection of class
External Edge guide X Axis
• Perform software update
• Check selection of class
External Edge guide Y Axis
• Check reference sensor
External Edge guide Y Axis
• Perform software update
• Replace the control
External Edge guide Y Axis
• Perform software update
• Check selection of class
235