Warning code
Warning name
(Hexadecimal)
0C4BH
Cam data writing
operation inhibit
0C50H
Outside cam auto-
generation cam No.
range
0C51H
Outside cam auto-
generation type
range
0C52H
Cam auto-generation
cam storage area
capacity over
0C53H
Cam auto-generation
cam open area
capacity over
0C54H
Outside cam auto-
generation value
range
0C55H
Cam auto-generation
calculation disable
0C56H
Cam auto-generation
data write inhibit
0C60H
Outside cam position
calculation cam No.
range
0C61H
Cam position
calculation cam not
registered
0C62H
Outside cam position
calculation cam axis
length per cycle
range
0C63H
Outside cam position
calculation cam axis
current value per
cycle range
0C64H
Cam position
calculation cam axis
1 cycle current value
calculation disable

Servo amplifier detection warning

For details of servo amplifier detection warnings, refer to each servo amplifier instruction manual.
12 TROUBLESHOOTING
588
12.4 List of Warning Codes
Error details and causes
Cam data writing operation is executed with the cam
data write password set.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
"[Cd.609] Cam auto-generation cam No." is outside the
range of 1 to 256.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
"[Cd.610] Cam auto-generation type" is other than 1.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
• The free area in the cam storage area is insufficient.
• The writable area is insufficient due to the decoupling
of free area.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
• The free area in the cam open area is insufficient.
• The writable area is insufficient due to the decoupling
of free area.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
"[Cd.611] Cam auto-generation data" is outside the
setting range.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
"[Cd.611] Cam auto-generation data" is set to the value
that the cam pattern cannot be generated. (Such as
when the sheet synchronization width is larger than the
sheet length in the cam for a rotary cutter)
[Operation status at warning occurrence]
Cam auto-generation is not executed.
Cam auto-generation is executed with the cam data
write password set.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
"[Cd.613] Cam position calculation: Cam No." is outside
the range of 0 to 256.
[Operation status at warning occurrence]
Cam position calculation is not executed.
Cam data of the specified cam No. does not exist on the
cam open area during the cam position calculation.
[Operation status at warning occurrence]
Cam position calculation is not executed.
"[Cd.615] Cam position calculation: Cam axis length per
cycle" is set to 0 or lower.
[Operation status at warning occurrence]
Cam position calculation is not executed.
"[Cd.617] Cam position calculation: Cam axis current
value per cycle" is outside the range of 0 to "Cam axis
length per cycle".
[Operation status at warning occurrence]
Cam position calculation is not executed.
Corresponding cam axis current value per cycle could
not be calculated during cam axis current value per
cycle calculation. (Occurs in reciprocated cam pattern)
[Operation status at warning occurrence]
Cam position calculation is not executed.
Remedy
Delete the cam data write password with a
programming tool.
Set a value within the range of 1 to 256.
Set 1.
• Decrease the number of cam data (number of cams,
cam resolution, and coordinate number).
• Erase the cam data and rewrite it.
• Decrease the number of cam data (number of cams,
cam resolution, and coordinate number).
• Erase the cam data and rewrite it.
Set a value within the setting range for the cam auto-
generation.
Review the setting value of the cam auto-generation
data.
Delete the cam data write password with a
programming tool.
Set a value within the range of 0 to 256.
• Specify the cam No. of an existing cam data.
• When writing the cam data from a peripheral
software, turn the PLC ready signal from OFF to ON
and open the cam data ON the cam open area.
Set a value within the range of 1 to 2147483647.
Set a value within the range of 0 to "Cam axis length
per cycle".
Set "[Cd.614] Cam position calculation: Stroke
amount", "[Cd.616] Cam position calculation: Cam
reference position", and "[Cd.618] Cam position
calculation: Cam axis feed current value" within the
range of reciprocated cam pattern stroke.