Setting positioning data
When using the JUMP instruction, set the following positioning data.
: Always set, : Set as required, : Setting not required
Setting item
[Da.1]
Operation pattern
[Da.2]
Control method
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time/JUMP destination positioning data No.
[Da.10]
M code/Condition data No./Number of LOOP to LEND repetitions
[Da.20]
Axis to be interpolated No.1
[Da.21]
Axis to be interpolated No.2
[Da.22]
Axis to be interpolated No.3
Refer to the following for information on the setting details.
Page 416 Positioning Data
Setting required/not required
(Set the JUMP instruction.)
(Set the positioning data No.1 to 600 for the JUMP destination.)
(Set the JUMP instruction execution conditions with the condition data
No.
0: Unconditional JUMP
1 to 10: Condition data No. ("Simultaneous start" condition data cannot
be set.))
3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
3
127