Mitsubishi Electric MELSEC iQ-FX5 User Manual page 221

Application
Table of Contents

Advertisement

Setting method
To use the "speed limit function", set the "speed limit value" in the parameters shown in the following table, and write them to
the Simple Motion module.
The set details are validated at the next start after they are written to the Simple Motion module.
Setting item
Setting
value
[Pr.8]
Speed limit
value
[Pr.31]
JOG speed limit
value
Refer to the following for the setting details.
Page 379 Basic Setting
• Parameters are set for each axis.
• It is recommended that the parameters be set whenever possible with the engineering tool. Execution by a
program uses many programs and devices. The execution becomes complicated, and the scan times will
increase.
Setting details
Set the speed limit value (max. speed during control).
Set the speed limit value during JOG operation (max. speed during control).
(Note that "[Pr.31] JOG speed limit value" shall be less than or equal to "[Pr.8]
Speed limit value".)
Factory-set initial value
200000
20000
7 CONTROL SUB FUNCTIONS
7.4 Functions to Limit the Control
7
219

Advertisement

Table of Contents
loading

Table of Contents