Mitsubishi Electric MELSEC iQ-FX5 User Manual page 497

Application
Table of Contents

Advertisement

[Cd.108] Gain changing command flag
• The command required to carry out "gain changing" of the servo amplifier from the Simple Motion module.
Fetch cycle: Operation cycle
If the setting is other than "0" and "1", operation is performed in the "gain changing" with the setting regard as
"0".
Refer to each servo amplifier instruction manual.
■Setting value
• Set with a decimal.
Setting
K
value
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 366 Axis control data
[Cd.112] Torque change function switching request
• Sets "same setting/individual setting" of the forward torque limit value or reverse torque limit value in the torque change
function.
Fetch cycle: Operation cycle
• Set "0" normally. (when the forward torque limit value and reverse torque limit value are not divided.)
• When a value except "1" is set, it operates as "forward/reverse torque limit value same setting".
■Setting value
• Set with a decimal.
Setting
K
value
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 366 Axis control data
Gain changing command flag
0: Gain changing command OFF
1: Gain changing command ON
Torque change function switching request
0: Forward/reverse torque limit value same setting
1: Forward/reverse torque limit value individual setting
10 DATA USED FOR POSITIONING CONTROL
10.8 Control Data
10
495

Advertisement

Table of Contents
loading

Table of Contents