Mitsubishi Electric MELSEC iQ-FX5 User Manual page 287

Application
Table of Contents

Advertisement

Setting method
Set "Valid/Invalid" by "[Pr.83] Speed control 10  multiplier setting for degree axis".
Normally, the speed specification range is 0.001 to 2000000.000 [degree/min], but it will be decupled and become 0.01 to
20000000.00 [degree/min] by setting "[Pr.83] Speed control 10  multiplier setting for degree axis" to valid.
To use the "Speed control 10  multiplier setting for degree axis function", set the parameters shown in the following table.
n: Axis No. - 1
Setting item
Speed control 10  multiplier
[Pr.83]
setting for degree axis
Refer to the following for the setting details.
Page 379 Basic Setting
Setting
Setting details
value
Set the speed control 10  multiplier setting for degree axis.
0: Invalid
1: Valid
Buffer memory address
63+150n
7 CONTROL SUB FUNCTIONS
7.9 Other Functions
7
285