[Cd.17] JOG speed
• Use this data item to set the JOG speed.
• The setting value range differs according to the "[Pr.1] Unit setting".
mm (  10
[Pr.1] Unit setting
Setting range
1 to 2000000000
*1 When "[Pr.83] Speed control 10  multiplier setting for degree axis" is valid, the setting range is 1 to 2000000000 (  10
Fetch cycle: At start
■Setting value
• Set with a decimal.
Actual value
[Cd.17] JOG speed
Conversion into an integer value
× 10
Setting value
R
(Decimal)
Example: When the "[Cd.17] JOG
speed" is set as "20000.00
mm/min", the buffer memory
stores "2000000".
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 366 Axis control data
[Cd.18] Interrupt request during continuous operation
• To interrupt a continuous operation, set "1" to this data item.
• After processing the interruption request ("1"), the Simple Motion module automatically resets the value to "0".
Fetch cycle: Operation cycle
■Setting value
• Set with a decimal.
Setting
K 1
value
The Simple Motion module resets the value to "0" automatically when the
continuous control interruption request is processed.
(This indicates the completion of continuous operation interruption request.)
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 366 Axis control data
-2
-3
inch (  10
mm/min)
1 to 2000000000
Unit conversion table ([Cd.17])
m
m
2
3
*1
3
0
*1: When "[Pr.83] Speed control
10 × multiplier setting for
degree axis" is valid: "2"
Interruption request continuous operation
1: Interrupts continuous operation control
or continuous path control.
*1
(  10
inch/min)
degree
1 to 2000000000
Unit
mm/min
inch/min
degree/min
pulse/s
10 DATA USED FOR POSITIONING CONTROL
-3
degree/min)
pulse (pulse/s)
1 to 1000000000
-2
degree/min).
10.8 Control Data
10
483