Mitsubishi Electric MELSEC iQ-FX5 User Manual page 511

Application
Table of Contents

Advertisement

Details of areas
Area name
Parameter area
Monitor data area
Control data area
Positioning data area (No.1 to 600)
Block start data area (No.7000 to 7004)
Servo parameter area
*1
Synchronous control area
*1
Cam area
*1 Refer to the following for details of synchronous control area and cam area.
MELSEC iQ-F FX5 Simple Motion Module User's Manual (Advanced Synchronous Control)
Data is backed up here.
Flash ROM
Parameter area (a)
Parameter area (b)
Parameter area (c)
Positioning data area
(No.1 to 600)
Block start data area
(No.7000 to 7004)
Internal memory
(nonvolatile)
Servo parameter area
Simple Motion module
Area name
Description
Parameter area (a)
Parameters validated when "[Cd.190] PLC READY
signal" changes from OFF to ON
Parameter area (b)
Parameters validated when the TO command is
executed from the CPU module (validated when the
next control is started after the TO command is
executed)
Parameter area (c)
Parameters validated with power supply ON/CPU
module reset
Description
Area where parameters, such as positioning parameters and home position return parameters, required for
positioning control are set and stored.
Area where the operation status of positioning system is stored.
Area where data for operating and controlling positioning system is set and stored.
Area where positioning data No.1 to 600 is set and stored.
Area where information required only when carrying out block No.7000 to 7004 high-level positioning is set
and stored.
Area where parameters, such as servo parameters, required for positioning control on servo amplifier are
set and stored.
Area where parameters and control data required for synchronous control are set and stored. Also, the
operation status of synchronous control is stored.
Area where cam data, etc. are set and stored. There are cam storage area and cam open area.
User accesses here.
Buffer memory/Internal memory
Parameter area (a)
Parameter area (b)
Parameter area (c)
Positioning data area
(No.1 to 600)
Block start data area
(No.7000 to 7004)
Servo parameter area
Monitor data area
Control data area
[Pr.1] to [Pr.7], [Pr.11] to [Pr.24], [Pr.43] to [Pr.57], [Pr.81] to [Pr.83],
[Pr.89] to [Pr.95], [Pr.116] to [Pr.119], [Pr.127], [Pr.150], [Pr.151],
[Pr.801], [Pr.805] to [Pr.807]
[Pr.8] to [Pr.10], [Pr.25] to [Pr.41], [Pr.84]
[Pr.91] to [Pr.94], [Pr.96], [Pr.97], [Pr.116] to [Pr.119], [Pr.150], [Pr.151],
[Pr.800] to [Pr.807]
10 DATA USED FOR POSITIONING CONTROL
10.9 Memory Configuration and Data Process
10
509