■Servo parameter of the buffer memory/internal memory
The followings show details about the operation timing and details at transmitting the servo parameter of the buffer memory/
internal memory.
• When the servo parameter is written in the internal memory (nonvolatile), it is unnecessary to use a setup
from the program/engineering tool.
• Axis connection time varies depending on the number of axes and the servo amplifier's power supply ON
timing. And, time when "20: Servo amplifier has not been connected/servo amplifier power OFF" is set in
"[Md.26] Axis operation status" is also varies.
• When the servo amplifier's power supply is turned ON before the system's power supply ON and the servo parameter
"[Pr.100] Servo series"  "0" is stored in the internal memory (nonvolatile)
Communication start timing with the servo amplifier
Servo parameter to be transferred
Simple
Motion
module
power ON
Servo parameter of buffer
memory/internal memory
Communication operation
status with servo amplifier
[Md.26] Axis operation status
• When the servo amplifier's power supply is turned ON before the system's power supply ON and the servo parameter
"[Pr.100] Servo series" = "0" is stored in the internal memory (nonvolatile)
Communication start timing with the servo amplifier
Servo parameter to be transferred
Simple
Motion
module
power ON
[Cd.190] PLC READY
signal
READY
([Md.140] Module status: b0)
Servo parameter of
buffer memory/
internal memory
Communication
operation status
with servo amplifier
[Md.26] Axis operation
status
10 DATA USED FOR POSITIONING CONTROL
520
10.9 Memory Configuration and Data Process
Initialization completion ((A) in the following figure)
The data stored (backed up) in the internal memory (nonvolatile).
Buffer memory/
internal memory
Initialization completion
data setting
of Simple Motion module (A)
Indefinite value
Communication invalid
0 (Standby)
20 (Servo amplifier has not been connected/servo amplifier power OFF)
The "[Cd.190] PLC READY signal" is turned ON from OFF. ((B) in the following figure)
The data written from the program/engineering tool before the "[Cd.190] PLC READY signal" ON. ((A)
in the following figure)
Initialization
completion
Buffer memory/
of Simple
internal memory
Motion
data setting
module
Indefinite value
Value of internal memory (nonvolatile)
Communication invalid
Communication start valid
0 (Standby)
20 (Servo amplifier has not been connected/servo amplifier power OFF)
Value of internal memory (nonvolatile)
Transfer the servo parameter at this point to the servo amplifier
Communication start (Axis connection)
Servo parameter setting from
the program/engineering tool (A)
CPU module
"[Cd.190] PLC READY signal"
RUN
OFF
ON (B)
Write value by the program/engineering tool
Transfer the servo parameter at this point to the servo amplifier
Communication start (Axis connection)
Axis connection completion
During communication
21 (Servo OFF)
Axis connection completion
During communication
21 (Servo OFF)