Mitsubishi Electric MELSEC iQ-FX5 User Manual page 609

Application
Table of Contents

Advertisement

Error code
Error name
(Hexadecimal)
1B02H
Home position
address setting error
1B03H
Home position return
speed error
1B06H
Creep speed error
1B09H
Home position return
retry error
1B0AH
Setting for the
movement amount
after proximity dog
ON error
1B0BH
Home position return
acceleration time
selection error
1B0CH
Home position return
deceleration time
selection error
1B0DH
Home position return
torque limit value
error
1B10H
Speed designation
during home position
shift error
Error details and causes
The setting value of the home position return basic
parameter "Home position address" is outside the
setting range.
[Operation status at error occurrence]
The READY signal ([Md.140] Module status: b0) is not
turned ON.
• The setting value of the home position return basic
parameter "[Pr.46] Home position return speed" is
outside the setting range.
• The setting value of the home position return basic
parameter "[Pr.46] Home position return speed"
exceeds the "[Pr.8] Speed limit value".
• The setting value of the home position return basic
parameter "[Pr.46] Home position return speed" is
smaller than "[Pr.7] Bias speed at start".
• The setting value of the home position return basic
parameter "[Pr.47] Creep speed" is outside the
setting range.
• The setting value of the home position return basic
parameter "[Pr.47] Creep speed" is larger than the
"[Pr.46] Home position return speed".
• The setting value of the home position return basic
parameter "[Pr.47] Creep speed" is smaller than the
"[Pr.7] Bias speed at start".
[Operation status at error occurrence]
The READY signal ([Md.140] Module status: b0) is not
turned ON.
The setting value of the home position return basic
parameter "Home position return retry" is outside the
setting range.
[Operation status at error occurrence]
The READY signal ([Md.140] Module status: b0) is not
turned ON.
The setting value of the home position return detailed
parameter "Setting for the movement amount after
proximity dog ON" is outside the setting range.
[Operation status at error occurrence]
The READY signal ([Md.140] Module status: b0) is not
turned ON.
The setting value of the home position return detailed
parameter "Home position return acceleration time
selection" is outside the setting range.
[Operation status at error occurrence]
The READY signal ([Md.140] Module status: b0) is not
turned ON.
The setting value of the home position return detailed
parameter "Home position return deceleration time
selection" is outside the setting range.
[Operation status at error occurrence]
The READY signal ([Md.140] Module status: b0) is not
turned ON.
• The setting value of the home position return detailed
parameter "Home position return torque limit value" is
outside the setting range.
• The home position return detailed parameter "Home
position return torque limit value" has exceeded the
detailed parameter 1 "Torque limit setting value".
[Operation status at error occurrence]
The READY signal ([Md.140] Module status: b0) is not
turned ON.
The setting value of the home position return detailed
parameter "Speed designation during home position
shift" is outside the setting range.
[Operation status at error occurrence]
The READY signal ([Md.140] Module status: b0) is not
turned ON.
Remedy
With the setting brought into the setting range, turn the
"[Cd.190] PLC READY signal" from OFF to ON.
• Correct the setting value and turn the "[Cd.190] PLC
READY signal" from OFF to ON.
• After the setting value is equal to or less than the
"[Pr.8] Speed limit value", turn the "[Cd.190] PLC
READY signal" from OFF to ON.
• After the setting value is set to equal to or more than
"[Pr.7] Bias speed at start", turn the "[Cd.190] PLC
READY signal" from OFF to ON.
• Correct the setting value and turn the "[Cd.190] PLC
READY signal" from OFF to ON.
• After the setting value is set to equal to or less than
the "[Pr.46] Home position return speed", turn the
"[Cd.190] PLC READY signal" from OFF to ON.
• After the setting value is set to equal to or more than
the "[Pr.7] Bias speed at start", turn the "[Cd.190]
PLC READY signal" from OFF to ON.
With the setting brought into the setting range, turn the
"[Cd.190] PLC READY signal" from OFF to ON.
With the setting brought into the setting range, turn the
"[Cd.190] PLC READY signal" from OFF to ON.
With the setting brought into the setting range, turn the
"[Cd.190] PLC READY signal" from OFF to ON.
With the setting brought into the setting range, turn the
"[Cd.190] PLC READY signal" from OFF to ON.
With the setting brought into the setting range, turn the
"[Cd.190] PLC READY signal" from OFF to ON.
With the setting brought into the setting range, turn the
"[Cd.190] PLC READY signal" from OFF to ON.
12 TROUBLESHOOTING
12.5 List of Error Codes
12
607

Advertisement

Table of Contents
loading