Errors related to synchronous control are described below.
Error code
Error name
(Hexadecimal)
1BA0H
Outside input axis
type setting range
1BA1H
Outside input axis
unit setting range
1BA2H
Outside input axis
unit conversion
denominator range
1BA3H
Outside input axis
length per cycle
range
1BA4H
Outside input axis
smoothing time
constant range
1BA5H
Outside input axis
rotation direction
restriction setting
range
1BA6H
Input axis unit
conversion overflow
1BA7H
Speed-position
switching control
start in servo input
axis not possible
1BA8H
Synchronous
encoder via servo
amplifier
communication error
1BA9H
Synchronous
encoder via servo
amplifier battery
error
12 TROUBLESHOOTING
610
12.5 List of Error Codes
Error details and causes
Setting values of input axis parameters "[Pr.300] Servo
input axis type" and "[Pr.320] Synchronous encoder
axis type" are outside the setting range.
[Operation status at error occurrence]
The setting becomes invalid for input axis.
Setting value of the input axis parameter "[Pr.321]
Synchronous encoder axis unit setting" is outside the
setting range.
[Operation status at error occurrence]
The setting becomes invalid for input axis.
The input axis parameter "[Pr.323] Synchronous
encoder axis unit conversion: Denominator" is set to 0
or lower.
[Operation status at error occurrence]
The setting becomes invalid for input axis.
The input axis parameter "[Pr.324] Synchronous
encoder axis length per cycle" is set to 0 or lower.
[Operation status at error occurrence]
The setting becomes invalid for input axis.
The input axis parameters "[Pr.301] Servo input axis
smoothing time constant" and "[Pr.325] Synchronous
encoder axis smoothing time constant" are set other
than 0 to 5000.
[Operation status at error occurrence]
The setting becomes invalid for input axis.
The input axis parameters "[Pr.304] Servo input axis
rotation direction restriction" and "[Pr.328] Synchronous
encoder axis rotation direction restriction" are set other
than 0 to 2.
[Operation status at error occurrence]
The setting becomes invalid for input axis.
Internal operation overflow occurred because the unit
conversion ratio (unit conversion: Numerator/unit
conversion: Denominator) of the input axis is too large.
[Operation status at error occurrence]
The input axis operation is immediately stopped, and a
connection becomes invalid.
When the input axis parameter "[Pr.300] Servo input
axis type" is feed current value or read current value,
the speed-position switching control is started with the
detailed parameter 1 "[Pr.21] Feed current value during
speed control" set to other than "1: Update of feed
current value".
[Operation status at error occurrence]
The speed-position switching control does not start.
• The hardware of the synchronous encoder or the
servo amplifier is faulty.
• The synchronous encoder cable is disconnected.
• Communication to the synchronous encoder cannot
be established.
[Operation status at error occurrence]
The connection of synchronous encoder axis becomes
invalid.
The battery which the servo amplifier connected
synchronous encoder is empty or the battery is
disconnected.
[Operation status at error occurrence]
The synchronous encoder control continues.
Remedy
Set a value within the setting range.
Set a value within the setting range.
Set a value within the range of 1 to 2147483647.
Set a value within the range of 1 to 2147483647.
Set a value within the range of 0 to 5000.
Set a value within the range of 0 to 2.
• Set a smaller unit conversion ratio (unit conversion:
Numerator/unit conversion: Denominator) of the
input axis.
• Decrease the input axis speed.
• Set "[Pr.300] Servo input axis type" to "Servo
command value" or "Feedback value".
• Set "[Pr.21] Feed current value during speed control"
to "1: Update of feed current value".
• Replace the synchronous encoder or the servo
amplifier.
• Check the synchronous encoder cable.
• Check the connected synchronous encoder.
• Check whether the synchronous encoder cable is
faulty.
Replace the battery or check the battery connection of
the servo amplifier.