[Md.130] F/W version
Stores the OS version of the module (F/W version).
Refresh cycle: At power supply ON
■Reading the monitor value
• Monitoring is carried out with a decimal display.
• When the F/W version of the Simple Motion module is Ver. 1.000
Monitor
1
0
value
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 363 System monitor data
[Md.131] Digital oscilloscope running flag
Stores the RUN status of digital oscilloscope.
Refresh cycle: Main cycle
■Reading the monitor value
• Monitoring is carried out with a decimal display.
Monitor
value
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 363 System monitor data
[Md.132] Operation cycle setting
Stores the current operation cycle.
Refresh cycle: At power supply ON
■Reading the monitor value
• Monitoring is carried out with a hexadecimal display.
Monitor
value
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 363 System monitor data
10 DATA USED FOR POSITIONING CONTROL
442
10.7 Monitor Data
● Storage value
0
0
OS version (F/W version)
Storage value
0: Stop
1: Run
-1: Stop by error
Storage value
0000: 0.888 ms
0001: 1.777 ms