Mitsubishi Electric MELSEC iQ-FX5 User Manual page 474

Application
Table of Contents

Advertisement

[Cd.42] Stop command processing for deceleration stop selection
• Sets the stop command processing for deceleration stop function (deceleration curve re-processing/deceleration curve
continuation).
Fetch cycle: At deceleration stop causes occurrence
■Setting value
• Set with a decimal.
Setting
K
value
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 366 System control data
[Cd.44] External input signal operation device (Axis 1 to 8)
• Operates the external input signal status (Upper/lower limit signal, proximity dog signal, stop signal) of the Simple Motion
module when "2" is set in "[Pr.116] FLS signal selection", "[Pr.117] RLS signal selection", "[Pr.118] DOG signal selection",
and "[Pr.119] STOP signal selection".
Fetch cycle: Operation cycle
■Setting value
• Set with a hexadecimal.
Setting
H
value
b15
b12
Buffer
memory
b15
b12
Buffer
Setting item
memory
Axis 1 Upper limit signal (FLS)
b0
Axis 1 Lower limit signal (RLS)
b1
Axis 1 Proximity dog signal (DOG)
b2
Axis 1 STOP signal (STOP)
b3
b4
Axis 2 Upper limit signal (FLS)
Axis 2 Lower limit signal (RLS)
b5
b6
Axis 2 Proximity dog signal (DOG)
b7
Axis 2 STOP signal (STOP)
Axis 3 Upper limit signal (FLS)
b8
b9
Axis 3 Lower limit signal (RLS)
Axis 3 Proximity dog signal (DOG)
b10
b11
Axis 3 STOP signal (STOP)
b12
Axis 4 Upper limit signal (FLS)
Axis 4 Lower limit signal (RLS)
b13
b14
Axis 4 Proximity dog signal (DOG)
b15
Axis 4 STOP signal (STOP)
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 366 System control data
10 DATA USED FOR POSITIONING CONTROL
472
10.8 Control Data
Stop command processing for
deceleration stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation
b8
b4
b0
External input signal
operation device
(Axis 5 to Axis 8)
b8
b4
b0
External input signal
operation device
(Axis 1 to Axis 4)
Default
Meaning
value
0
0
When "[Pr.22]
0
Input signal
0
logic selection"
0
is negative
0
logic
0
0: OFF
0
1: ON
0
When "[Pr.22]
0
Input signal
0
logic selection"
0
is positive logic
0
0: ON
0
1: OFF
0
0
Buffer
Setting item
memory
Axis 5 Upper limit signal (FLS)
b0
Axis 5 Lower limit signal (RLS)
b1
Axis 5 Proximity dog signal (DOG)
b2
Axis 5 STOP signal (STOP)
b3
b4
Axis 6 Upper limit signal (FLS)
Axis 6 Lower limit signal (RLS)
b5
b6
Axis 6 Proximity dog signal (DOG)
b7
Axis 6 STOP signal (STOP)
Axis 7 Upper limit signal (FLS)
b8
b9
Axis 7 Lower limit signal (RLS)
Axis 7 Proximity dog signal (DOG)
b10
b11
Axis 7 STOP signal (STOP)
b12
Axis 8 Upper limit signal (FLS)
Axis 8 Lower limit signal (RLS)
b13
b14
Axis 8 Proximity dog signal (DOG)
b15
Axis 8 STOP signal (STOP)
Default
Meaning
value
0
0
When "[Pr.22]
0
Input signal
0
logic selection"
0
is negative
0
logic
0
0: OFF
0
1: ON
0
When "[Pr.22]
0
Input signal
0
logic selection"
0
is positive logic
0
0: ON
0
1: OFF
0
0

Advertisement

Table of Contents
loading

Table of Contents