[Md.51] Amplifier-less operation mode status
Indicates a current operation mode.
Refresh cycle: Immediate
■Reading the monitor value
• Monitoring is carried out with a decimal display.
Monitor
Storage value
value
0: Normal operation mode
1: Amplifier-less operation mode
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 363 System monitor data
[Md.52] Communication between amplifiers axes searching flag
Stores the detection status of axis that set communication between amplifiers.
Refresh cycle: Immediate
■Reading the monitor value
• Monitoring is carried out with a decimal display.
Monitor
Storage value
value
0: Search end
1: Searching
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 363 System monitor data
[Md.53] SSCNET control status
Stores the connect/disconnect status of SSCNET communication.
Refresh cycle: Immediate
■Reading the monitor value
• Monitoring is carried out with a decimal display.
Monitor
value
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 363 System monitor data
[Md.59] Module information
Stores the model code of the module.
Refresh cycle: At power supply ON
■Reading the monitor value
• Monitoring is carried out with a hexadecimal display.
Monitor
6
3
C
value
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 363 System monitor data
Storage value
1: Disconnected axis existing
0: Command accept waiting
-1: Execute waiting
-2: Executing
Storage value
0: 4 axes
1: 8 axes
10 DATA USED FOR POSITIONING CONTROL
10.7 Monitor Data