Monitoring the current value
The "feed current value" and "machine feed value" are stored in the following buffer memory addresses, and can be read
using a "DMOV(P) instruction" from the CPU module.
n: Axis No. - 1
Monitor item
[Md.20]
Feed current value
[Md.21]
Machine feed value
Program example
The following shows the program example that stores the feed current value of the axis 1 in the specified device when X40 is
turned ON.
■For using labels
Classification
Label name
Module label
FX5SSC_1.stnAxMntr_D[0].dCommandPosition_D
Global label, local
Defines the global label or the local label as follows. The settings of Assign (Device/Label) are not required for the label that the
label
assignment device is not set because the unused internal relay and data device are automatically assigned.
■For using buffer memory
3 MAJOR POSITIONING CONTROL
60
3.1 Outline of Major Positioning Controls
Buffer memory addresses
2400+100n
2401+100n
2402+100n
2403+100n
Description
Axis 1 Feed current value