I/O Assembly and
Reference Data
See the tables for I/O assembly and reference data.
1791DS-IB12, 1791DS-IB8XOB8, 1791DS-IB4XOW4 Data
The bits in the tag definitions of RSLogix 5000 and RSNetWorx for
DeviceNet software are different than those shown in the following
section. The following table defines the name associations for
consistency with the programming software.
Bit Definitions and RSLogix 5000 Tag Names
Bit Definitions
Safety Input 0
Safety Input 11
Safety Input 0 Status
Safety Input 11 Status
Safety In Status
Muting Lamp Status
Safety Output 0
Safety Output 7
Standard Output 0
Standard Output 3
Safety Output 0 Status
Safety Output 7 Status
Safety Out Status
Safety Output 0 Monitor
Safety Output 7 Monitor
Test Output 0 Status
Test Output 3 Status
Configuration Reference Information
RSLogix 5000 Tag Name
Pt00Data
Pt11Data
Pt00InputStatus
Pt11InputStatus
InputStatus
MutingStatus
Pt00Data
Pt07Data
Test00Data
Test03Data
Pt00OutputStatus
Pt07OutputStatus
OutputStatus
Pt00Readback
Pt07Readback
Pt00TestOutputStatus
Pt03TestOutputStatus
Publication 1791DS-UM001H-EN-P - April 2009