Rockwell Automation 1732DS-IB8 User Manual page 54

Guard i/o devicenet safety modules
Hide thumbs Also See for 1732DS-IB8:
Table of Contents

Advertisement

50
Configure Modules in RSLogix 5000 Software
Data
Input data
Safety Input Data
SAFETY
Combined Safety Input Status
SAFETY
Individual Safety Input Status
SAFETY
Combined Safety Output Status
SAFETY
Individual Safety Output Status
SAFETY
Muting Lamp Status
SAFETY
Output Readback
STANDARD
Individual Test Output Status
STANDARD
Output data
Safety Output Data
SAFETY
Standard Output Data
STANDARD
Publication 1791DS-UM001H-EN-P - April 2009
Values and States of Tags
This table shows the values and states of the tags.
Description
Indicates the ON/OFF status of each input terminal.
• ON: 1 OFF: 0
An AND of the status of all input terminals.
• All terminals are normal: 1
• An error was detected in one or more input terminals: 0
Indicates the status of each input terminal.
• Normal (OK): 1 Fault (Alarm): 0
An AND of the status of all safety output terminals.
• All terminals are normal: 1
• An error has been detected in one or more output terminals: 0
Indicates the status of each safety output terminal.
• Normal (OK): 1 Fault (Alarm): 0
Indicates the status when terminal T3 is configured as the muting lamp output.
• Normal (OK)l: 1 Fault (Alarm): 0
Monitors the presence of 24V on the output terminal. Readback is ON (1) if 24V is
on output terminal.
• ON: 1 OFF: 0
Indicates the status of each of the test output terminals.
• Normal (OK): 1 Fault (Alarm): 0
Controls the safety output.
• ON: 1 OFF: 0
Controls the test output when Test Output mode is set to a standard output.
• ON: 1 OFF: 0
Safety denotes information the controller can use in
IMPORTANT
safety-related functions. Standard denotes additional
information that must not be relied on for safety functions.