HEIDENHAIN MSE 1000 Operating Instructions Manual page 163

Table of Contents

Advertisement

Verify workstation IP settings
The settings configured for the workstation IP address and netmask in MSEsetup
must match the settings for the workstation NIC.
Look up the IP address and netmask of the workstation NIC using Ipconfig, see
"Command line tools", page 161.
Open MSEsetup.
Open the Connect screen, see "Connect screen", page 77.
Set the Workstation IP and netmask to match the values of the workstation
NIC, see "Workstation IP", page 79.
Restart MSEsetup.
Verify module IP settings
MSE 1000 module subnet and netmask settings must match the settings applied
to the Workstation IP and netmask.
Open the Logging screen, see "Logging", page 118.
Open the Service Log file, see "Service log", page 120.
Power cycle the module chain, see "Power cycling", page 48.
The IP address and netmask of each module is broadcast once every 10 seconds.
Verify that the subnet and netmask of each module matches the workstation
subnet and netmask.
Verify firewall settings
If a firewall is being used:
Verify that a firewall is not blocking communication, see "Firewall configuration",
page 86.
Verify communication
Verify communication between the workstation and the modules by using the
Ping tool, see "Command line tools", page 161.
Verify crossover cable
If a DHCP router is not being used (static IP addresses):
Verify that an RJ-45 crossover cable is being used if required. Some NIC's do
not require the use of a crossover cable. Refer to the documentation provided
with the workstation or NIC for additional information.
DHCP router configuration
If a DHCP router is being used:
Use IpConfig to verify that the workstation sees the router as a gateway.
Verify that the DHCP router settings are correct, see "Configuring the module
chain with DHCP", page 87.
HEIDENHAIN | MSE 1000 | Operating Instructions | 10/2015
Network troubleshooting 12.13
12
163