9
Operating information
9.4
Asynchronous message thread
Request
Toggle Output
Set Output
Set Latch
122
Parameters
A value of 151 must be put in the UDP packet.
A module number must be put in the UDP packet.
The required output number must be put in the UDP
packet (1-4).
The value is not used.
Toggles the desired output.
No response is sent back.
A value of 152 must be put in the UDP packet.
A module number must be put in the UDP packet.
The required output number must be put in the UDP
packet (1-4).
The value must be 0 for off or 1 for on.
Sets the output to the desired value.
No response is sent back.
A value of 153 must be put in the UDP packet.
The moduleNum is not used.
The channelNum is not used.
The value is used to determine which latch line to trig-
ger (1-5).
A latch command is sent to the modules causing
the data to be updated in the Data screen and the
Mse1000Data.xlsx Excel spreadsheet.
No response is sent back.