12
Troubleshooting
12.1
Diagnostics
Function reserves
The Function Reserves screen is used to display absolute track, incremental track
and position value formation bar diagrams. The result is displayed in %. A drag
indicator (square above the bar display) marks the minimum.
Function reserves ranges:
Green range:
Yellow range:
calculation errors are to be expected. No alarms are generated, warnings may
occur.
The yellow range indicates service or maintenance recommended.
Refer to the documentation provided with the encoder for additional information
on EnDat function reserves.
Function reserves:
Absolute track
Incremental track
Positions value
Function reserves screen
146
The output signal is within the specifications.
The output signal is outside the specifications, but no counting or