Troubleshooting
12.1
Diagnostics
EnDat diagnostics
EnDat diagnostics are used to verify that an EnDat encoder is operating properly.
EnDat device diagnostics:
Warnings
Errors
Function reserves
Warnings and errors
The EnDat warnings and errors screen is used to display any warnings or errors
that may be present for the encoder connected to the selected channel.
The current status of a warning or error is displayed in a color coded square next to
the name of the warning or error.
Color codes:
Green:
Yellow:
Red:
An error exists for the connected encoder.
Grey:
Warning or error is not supported by the connected encoder.
A Warnings indicates that certain tolerances of the encoder were reached or
exceeded, but the position value is not incorrect. An Error becomes active if there
is a malfunction in the encoder that is presumably causing incorrect position
values.
Refer to the documentation provided with the encoder for additional information
on EnDat warnings and errors.
EnDat warnings and errors:
Warnings
Frequency Exceeded
Temperature Exceeded
Light Control Reserve
Battery Charge Low
Traverse Reference Point
144
No warning or error exists for the connected encoder.
A warning exists for the connected encoder.
Errors
Light Unit
Signal Amplitude
Position Error
Overvoltage
Undervoltage
Overcurrent
Battery Failure