12.9
Module chain reconnect warning
Warning
The module chain needs to be
reconnected
12.10 Referencing warning
Warning
Referencing has not been com-
pleted
12.11 Referencing error
Error
Referencing failed
HEIDENHAIN | MSE 1000 | Operating Instructions | 10/2015
Cause
This warning occurs when a
module has been rebooted
or added to the module chain
without a reconnect or broad-
cast.
Modules send out broadcasts
once every 30 seconds with
their network information until
they obtain a connection from
MSEsetup. The service log will
show information regarding
the module that is sending the
broadcast.
Cause
Reference marks on 1 V
PP
encoders have not been tra-
versed.
Cause
The referencing mark type, line
count, or signal period may be
incorrect for a 1 V
or TTL en-
pp
coder. The interpolation may be
incorrect for a TTL encoder.
Referencing error 12.11
Corrective action
Click the Delete all errors
button to clear the warning.
A dialog window appears
requesting confirmation
to recover from lost
communication.
Click the OK button.
MSEsetup performs a
reconnect.
A Broadcast must be
performed if a new module has
been added to the chain, see
"Connection", page 81.
Corrective action
Traverse reference marks on
1 V
encoders.
PP
Further Information:
"Referencing", page 109.
Corrective action
Change the referencing
mark type, line count, signal
period, or interpolation to
the correct value.
12