I/O references for the Analog Output Module can be set in the same way as for the
INFO
Analog Input Module.
4) Setting the Mode
Press the F4 (Zoom) Key to access to the Parameter Setting Screen (I/O Map Mod-
ule Editor).
(1) Move the cursor to Mode and press the Enter Key to access the mode setting.
(2) A screen will appear so that the mode setting can be selected.
Move the cursor to either 0 - 4000 MODE or -2000-+2000 MODE and press the
Enter Key to select the desired mode.
The MEMOSOFT is set by default as follows:
• Modules of the signal range ±10V: -2000-+2000 MODE
• Modules of the signal range 0 to 10V: 0 - 4000 MODE
• Modules of the signal range 0 to 5V: 0 - 4000 MODE
• Modules of the signal range 4 to 20-mA: 0 - 4000 MODE
5) Setting the Service Scan
Make sure that the Parameter Setting Screen (I/O Map Module Editor) is being dis-
played.
Fig. 4.13 Parameter Setting Screen: Mode
Fig. 4.14 Mode Selection
4-47
4.4 Operations Using MEMOSOFT