YASKAWA MEMOCON GL120 User Manual page 251

Table of Contents

Advertisement

6 Installation and Wiring
6.2.3 Wiring DC I/O Modules
Name
Model Name
Model No.
Length (L)
Cable Specifications
Terminals
c) Use the following electric wires and connectors to assemble I/O signal cables to con-
nect to these Digital I/O Modules:
• Cable size: 0.26mm
• Module side connector (provided as accessory):
Connector: FCN-361J040-AU (soldered) (manufactured by Fujitsu Ltd.)
Cover: FCN-360C040-B (manufactured by Fujitsu Ltd.)
d) If a W5410 64-point I/O Module Cable is used, select the appropriate cable from the
following table.
Table 6.12 W5410 64-point I/O Module Cables
Item
W5410 Cable
W5410-05
JEPMC-W5410-05
0.5m
Shielded cable of 40 conductors, AWG24 (0.20 mm
Module Side
Connector: FCN-363J-040 (manufactured by Fujitsu Ltd.)
External
Loose wires; Cable length: 100 mm, pin number labeled on each wire
device Side
As shown in the following figure, the external-device end of the W5410 cable has
loose wires. The size of each wire is 0.20 mm
Connector (Module side)
Model name
e) If using an insulation transformer for the primary side of the DC-voltage stabilizing
power supply, make sure to separate the primary and the secondary coils. If using a
noise filter, also be sure to separate the primary and the secondary coils.
2
(AWG23)
Specifications
W5410-10
JEPMC-W5410-10
1.0m
FCN-360C040-B (manufactured by Fujitsu Ltd.)
FCN-363J-AU/R (manufactured by Fujitsu Ltd.)
2
A pin number label is on
each loose wire.
Shielded cable
L
6-24
W5410-30
JEPMC-W5410-30
3.0m
2
)
.
Loose wires (external-device side)
100 mm
40-core
loose wires