RMON Commands
rmon alarm
SPS208G/SPS224G4/SPS2024 Command Line Interface Reference Guide
type
— Specifies the method used for sampling the selected variable and
calculating the value to be compared against the thresholds. Possible
values are absolute and delta.
If the method is absolute, the value of the selected variable is compared
directly with the thresholds at the end of the sampling interval. If the method
is delta, the selected variable value of the last sample is subtracted from the
current value, and the difference is compared with the thresholds.
direction — Specifies the alarm that may be sent when this entry is first set
to valid. Possible values are rising, rising-falling and falling.
If the first sample (after this entry becomes valid) is greater than or equal to
rthreshold
direction
and
generated. If the first sample (after this entry becomes valid) is less than or equal
fthreshold
direction
to
and
generated.
name
— Specifies the name of the person who configured this alarm. If
unspecified, the name is an empty string.
Default Configuration
The type is absolute.
The startup direction is rising-falling.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the following alarm conditions:
Alarm index — 1000
Variable identifier — LinkSys
is equal to rising or rising-falling, a single rising alarm is
is equal to falling or rising-falling, a single falling alarm is